Table of Contents Table of Contents
Previous Page  10-11 / 64 Next Page
Information
Show Menu
Previous Page 10-11 / 64 Next Page
Page Background

Easier and Quicker Blood Absorption

test your blood glucose within 5~7 seconds.

2) Advanced Superior Sip-In

Technology

1) Greater Accuracy According to

Full ISO 15197:2013

Improves overall test experience

and testing precision.

Scan to view the video

on ASSI technology

TOP COVER

HYDROPHILIC

LAYER

GLUE LAYER

SPACER

ISOLATION

PRINTING-LAYER

PET

PRINTING-LAYER

SILVER

PRINTING-LAYER

CARBON

PRINTING-LAYER

0.25 Sec.

Easier strip handling

test your blood glucose at any angle.

This icon represents ForaCare’s promise and

commitment to delivering the highest quality of

diabetes self-care through innovative technologies

and solutions. It symbolizes the complete assurance

in higher measuring accuracy that we offer in blood

glucose testing.

ISO 15197:2013

, the revised requirements for blood

glucose monitoring systems for self-testing in managing diabetes

mellitus, has been published to enforce a stricter accuracy and precise

guidelines for blood glucose meters used for self-measurement by lay persons.

Absolute differences between FORA Diamond MINI andYSI 2300 STAT PLUS™

-120

-100

-80

-60

-40

-20

0

20

40

60

80

100

120

0

50

100

150

200

250

300

350

400

450

500

550

Glucose concentration (YSI2300STATPLUS™) [mg/dl]

FORADiamondMINI -YSI 2300STATPLUS™ [mg/dl]

Lot_1

Lot_2

Lot_3

DINEN ISO 15197:2003 limits

ISO 15197:2013 limits

TD13I215-BOE

TD13G115-BOE

TD1 H225-BOE

Clinically Validated

at ForaCare

facilities, according to the latest clinical

standards and guidelines.

ACCURACY STANDARD

Blood

glucose

levels

< 100mg/dL

(5.55 mmol/L)

< 75mg/dL

(4.2 mmol/L)

≥ 100mg/dL

(5.5 5mmol/L)

≥ 75mg/dL

(4.2 mmol/L)

± 15mg/dL

(0.83 mmol/L)

± 15mg/dL

(0.83 mmol/L)

± 15%

± 20%

ISO 15197 : 2013

ISO 15197 : 2003

FORA

®

Diamond series blood glucose monitoring systems offer 24 unique

features, each designed with high specifications for a precise, reliable and

comfortable blood glucose testing experience.

24 Reasons for a

FORA

®

Diamond

Criteria

ISO

15197:2013

1. Scope

2. Normative References

3. Terms and Definitions

4. Design and Development

5. Safety and Reliability Testing

6. Analytical Performance Evaluation 95% of the measurement to fall:

±15mg/dL at glucose concentrations < 100mg/dL(<5,55mmol/L)

±15% at glucose concentrations ≥ 100mg/dL(≥5,55mmol/L)

7. Information Supplied by the Manufacturer

8. User Performance Evaluation

Full ISO

15197:2013

Diabetes Care